Philmore 50A Push Button Manual Reset Thermal Circuit Breaker 50V DC, 125V AC. Philmore circuit breakers are single pole, thermal circuit breakers that feature a recessed reset button which cannot be manually pulled out to disconnect the circuit. When an overload occurs and the breaker opens, it allows the reset button to “pop out” for visible trip indication. The recommended mounting hole is 0.437 (7/16). Philmore circuit breakers are UL 1077 recognized as supplementary protectors, File E99607, and CSA Certified as appliance Components protectors, File LR62590. Endurance: 1,000 times at least. Calibration: Breaker will continuously carry 100% of rated load. It may trip between 101% and 144% of rated load, but must trip at 145% at 25º C. Dielectric Strength: Over 1,500 volts RMS. Max. Operating Voltages: 50VDC, 250VAC. Interrupt Capacity: 2,000 Amps, at 50. VDC(1-30 amp Models) 1,000 Amps, at 250VAC (1-30 amp Models).
Product image
B00OGL697M

Availability: Currently unavailable

Score: 13.699

Category: Tools

Rating: 5

Votes: 3

Find similar products
4 AMP 50VDC, 250VAC CIRCUIT BREAKER. Philmore circuit breakers are single pole, thermal circuit breakers that feature a recessed reset button which cannot be manually pulled out to disconnect the circuit. When an overload occurs and the breaker opens, it allows the reset button to “pop out” for visible trip indication. The recommended mounting hole is 0.437 (7/16). Philmore circuit breakers are UL 1077 recognized as supplementary protectors, File E99607, and CSA Certified as appliance Components protectors, File LR62590. Endurance: 1,000 times at least. Calibration: Breaker will continuously carry 100% of rated load. It may trip between 101% and 144% of rated load, but must trip at 145% at 25º C. Dielectric Strength: Over 1,500 volts RMS. Max.
Product image
B09LJ2DDQQ

Price: $10.01

Score: 9.009

Category: Tools

Rating: 4.6

Votes: 57

Find similar products
20A, 240V AC, 60V DC, 1 Pole, DIN Rail Mount Miniature Circuit Breaker, Trip Curve: C, UL1077. The ASI NDB2-63C20-1 standard DIN rail mount single pole AC Circuit Breaker is a 18 mm thermal magnetic breaker rated at 20 amp, 240V. The UL 1077 supplemental protection circuit breaker is 300 % factory tested to quality and reliability. The circuit breaker features visual trip indication, easy to wire screw clamp connections and mounts on the industry standard 35 mm DIN rail. The NDB2 series of circuit breakers can be used in most industrial applications and are an ideal drop-in replacement to existing supplemental circuit breakers. The NDB2-63C20-1 uses the general purpose C curve trip characteristics which is instantaneous trip 5In to 10In. Matching accessories are available including auxiliary contact, alarm contact and bus bars.
Product image
B0088BE8H4

Availability: Currently unavailable

Score: 8.772

Category: Tools

Rating: 4.4

Votes: 16

Find similar products
MP235 35-Amp Double Pole Type MP-T Circuit Breaker. Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home’s electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current. Murray strongly recommends against the use of used breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.
Product image
B007IAG522

Price: $49.99

Score: 8.621

Category: Tools

Rating: 4.4

Votes: 76

Find similar products
Square D - QOT1520 QO 1-15-Amp 1-20-Amp Single-Pole Tandem Circuit Breaker. The Square D by Schneider Electric QO 15 & 20 Amp Single-Pole Tandem Circuit Breaker is intended for overload and short-circuit protection of your electrical system. This breaker offers 2 circuits in the space of just 1 and is compatible with QO load centers, CSED devices and NQOD panel boards. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between OFF and ON and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
Product image
B00A2BK2F0

Price: $11.15

Score: 8.621

Category: Tools

Rating: 4.5

Votes: 197

Find similar products
HOM230 HOME LINE Circuit Breakers for residential use. Square D Homeline™ Standard 2-Pole 1-Phase miniature circuit breaker is rated at 30 Amps and 120/240 Volt AC at 50/60 Hz. Interrupt current rating of this circuit breaker is 10 Kilo-Amps. It measures 2.98 Inch x 3.13 Inch x 2 Inch. This 2-space circuit breaker with clamp terminal connection, accommodates aluminum/copper wire of size 14 - 8 AWG and copper wire of size 14 - 10 AWG. It features thermal-magnetic trip function. HACR rated circuit breaker offers plug-in mounting. It is suitable.
Product image
B00KHRE87W

Availability: Currently unavailable

Score: 8.475

Category: Tools

Rating: 5

Votes: 1

Find similar products
uxcell 2Pcs Reset Thermal Overload Protector Circuit Breaker AC 125V 250V 15A. Hs-r01thermal overload protector features AC 125/250V 15a, designed with 10Mm diameter thread, Black plastic case, reset; button, easy to install. Wonderful protector for air compressor and other electric appliances.
Product image
B005D6DLEI

Availability: Currently unavailable

Score: 8.403

Category: Tools

Rating: 4.6

Votes: 19

Find similar products
MP280 80-Amp Double Pole Type MP-T Circuit Breaker. Product Description Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home’s electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current. Murray strongly recommends against the use of used breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so. From the Manufacturer Murray plug in circuit breakers are intended for use in Murray load centers or meter combinations. The double pole Murray breakers may be used in 1 or 3-phase load centers and are 240V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required.
Product image
B00OT3KYXM

Price: $17.8

Score: 8.333

Category: Tools

Rating: 4.6

Votes: 560

Find similar products
MP120 20-Amp Single Pole Type MP-T Circuit Breaker. Product Description Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home’s electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current. Murray strongly recommends against the use of used breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so. From the Manufacturer Murray plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in single or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required.
Product image
B00NVJ25UU

Price: $14.62

Score: 8.333

Category: Tools

Rating: 4.4

Votes: 6

Find similar products
15 Amp Manual-Reset Low-Profile ATC/ATO Blade-Style Circuit Breakers (1 per Pack). 15 amp manual-reset low-profile ATC/ATO blade-style circuit breakers. 12-24 VDC. These circuit breakers are suitable replacements for Low-Profile ATO and Low-Profile ATC circuit breakers and fuses. They are thin with a low profile to fit into spaces where clearance is an issue. These type III circuit breakers reset with a push of a button.