E-commerce Search Demo
AI Assisted Filters
Parameters
Query:
Category filters: All
AI Assist: ON
Page: 1
Products
Time taken: 4 Max score: 1000.000 Total hits: 600 Full time: 0.0 s
Showing 1-10 of 600 products
![]() B00P997PDC Availability: Currently unavailable Score: 1000.000 Category: Tools Rating: 5 Votes: 1 Find similar productsGED THQLLX4 GENERATOR INTERLOCK KIT. Mfr Brand Name: GE / Catalog No.: THQLLX4 / Product Name: GE THQLLX4 N NEW / **: Interlock Kit / **: Meter Socket Load Center. | ![]() B000BPF0I6 Availability: Currently unavailable Score: 6.135 Category: Tools Rating: 4.1 Votes: 28 Find similar productsGE Energy Industrial Solutions THQMV200D Main Breaker Kit for GE Load Centers, 200-Amp. It is 200A Main Breaker Kit For GE Load Centers Mounts Vertically To Enable Top Or Bottom Feed For Use In New TLM2020CCU Powermark Gold Main Lug Load Center True Value #393-967. |
![]() B086Q41H4H Price: $48.77 Score: 5.780 Category: Tools Rating: 4.8 Votes: 242 Find similar productsNSD200A Square D Generator Interlock kit QO and Homeline - Anodized. GenSafety manufactures a very high quality line of generator breaker interlock kits. These interlocks are made of heavy guage CNC machined aluminum and are then color anodized for a long lasting professional appearance. The kits come with everything needed to complete the job. The National Electric Code requires a generator interlock device when powering a breaker panel with a generator. Failure to install an interlock could have fatal consequences to a lineman or utility worker! Once you have seen the quality of a GenSafety Interlock kit you won't settle for anything else. These interlocks look professional and they make you look professional as well! Please note - We do NOT sell this kit in New Jersey. | ![]() B007ZZGTE4 Price: $10.99 Score: 5.587 Category: Tools Rating: 4.9 Votes: 11 Find similar productsSIEMENS EC3GB30 Ground Bar Kit with 30 Terminal Positions. EC3GB series ground bars are intended for use in Siemens ES and PL series of load centers with a box height of 24, 27, 29, 30, 35, 36, 38, or 42 inches. For the ES and PL lines of load centers this would include 125A load centers of 24 1-Inch spaces or more, 150A and 200A load centers of 20 1-Inch spaces or more, and all 225A load centers. The ground bars can be mounted in one of 4 locations inside the load center: top right, top left, bottom right, and bottom left. Up to 4 ground bars can be added to each load center. |
![]() B007ZZGSWC Price: $6.65 Score: 5.556 Category: Tools Rating: 4.4 Votes: 8 Find similar productsSIEMENS EC3GB27 Ground Bar Kit with 27 Terminal Positions. EC3GB series ground bars are intended for use in Siemens ES and PL series of load centers with a box height of 24, 27, 29, 30, 35, 36, 38, or 42 inches. For the ES and PL lines of load centers this would include 125A load centers of 24 1-Inch spaces or more, 150A and 200A load centers of 20 1-Inch spaces or more, and all 225A load centers. The ground bars can be mounted in one of 4 locations inside the load center: top right, top left, bottom right, and bottom left. Up to 4 ground bars can be added to each load center. | ![]() B0758QGX89 Price: $425 Score: 5.525 Category: Tools Rating: 4.6 Votes: 7 Find similar productsChallenger Thomas & Betts Meter Socket Breaker Buss Repair Kit. Thomas & Betts type MM breaker buss repair kit.This kit will fit the obsolete type MM , MP,WM and M3M 125 amp max meter sockets made by Challenger, Westinghouse and Thomas & Betts.These sockets have the breaker directly under the meter!!!. Rated 120/240 volt 125 amp this buss kit accepts Thomas & Betts type TB, Westinghouse type BR or Challenger type C plug in breakers up to 125 amp.breakers are not included Buyer will receive one breaker buss kit including the insulator as in picture. This kit is after market , but are not orginal manufacturers parts. !Meter stack or socket is not included! See our other listings for meter socket kits or other parts Returns are limited to exchange only!NO REFUNDS! Email your questions or pictures of your stack if your not sure this will fit!!! We buy meter sockets, stacks, ect.send us your list!!. |
![]() B09NRR7YCH Price: $30.98 Score: 5.525 Category: Tools Rating: 4.3 Votes: 15 Find similar productsZTTXL Generator Interlock Kit Compatible with Murray or Siemens 150 amp or 200 amp Panels , 7/8 - 1 1/4 inches Spacing Between Main and Branch Breaker, Professional and Interlock Kit New. . | ![]() B00317BFZS Price: $10.18 Score: 5.525 Category: Tools Rating: 4.6 Votes: 18 Find similar productsSIEMENS ECGB14 Ground Bar Kit with 14 Terminal Positions. The ECGB series of ground bars are intended for use on Siemens EQ and Ultimate brand of load centers. Load centers would include all catalog numbers that begin with an E, W, or G. |
![]() B097ZJB5M1 Availability: Currently unavailable Score: 5.464 Category: Tools Rating: 3 Votes: 1 Find similar productsGenerator Interlock kit, HOMRBGK2C Outdoor Cover Generator and QOM2 Frame Size Main Breaker Interlock Kit, Compatible with Outdoor Homeline 150A-225A Main Breaker Load Centers Aftermarket Part. Generator Interlock kit, HOMRBGK2C Outdoor Cover Generator and QOM2 Frame Size Main Breaker Interlock Kit, Compatible with Outdoor Homeline 150A-225A Main Breaker Load Centers. | ![]() B005GLCEZM Price: $70.05 Score: 5.464 Category: Tools Rating: 3.9 Votes: 11 Find similar productsSiemens ECSBPK07 Standby Power Mechanical Interlock for Use on Meter Combinations. Amazon.com Siemens standby power mechanical interlock kits provide a means to ensure that the main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. This model (ECSBPK07) is designed for use on load centers or meter combinations that will accept two QNR (MD-TR) circuit breakers side by side or will accept two QN (MD-T) circuit breakers. It's compatible with QNR, QNRH, HQNR, QN, QNH, and HQN utility main breaker and standby main breaker types. The most common application for an interlock kits is when a portable generator is used to provide back up power to a building. If the utility main breaker in a panel is left in the -ON-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK07 interlock kit ( view larger ). Use on Siemens or Murray panels ( view larger ). ECSBPK07 Generator Standby Power Mechanical Interlock At a Glance UL listed for use in most Siemens load centers and meter combinations UL listed for use in most Siemens load centers and meter combinations Remains attached to the main breakers when load center cover Remains attached to the main breakers when load center cover Corrosion resistant finish Corrosion resistant finish For use on Siemens or Murray panels For use on Siemens or Murray panels Easy assembly requiring no modifications to the load center or meter combination Easy assembly requiring no modifications to the load center or meter combination Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code From the Manufacturer Siemens standby power mechanical interlock kits provide a means to ensure that the Main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. The most common application for these kits is when a portable generator is used to provide back up power to a building. If the utility Main breaker in a panel is left in the -ON-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK07 will work on any Siemens or Murray Load Center in which the Main breaker and standby power breaker are backfed, two pole, QP or MP type breakers. |









